EM19-7003
EONMACH
8412299090
| Availability: | |
|---|---|
| Quantity: | |
Customized Hydraulic Power Pack for Lift Cargo Ladder.
Hydraulic power unit (hydraulic freight elevator)
-Extremely load-bearing: can easily drive 2-10 tons of heavy load, suitable for factory/warehouse heavy cargo transportation.
-Simple structure: the core is motor + oil pump + oil tank, with few components, low fault and easy troubleshooting.
-Flexible installation: no need for machine room, deep pit, low requirements for hoistway and low civil construction cost.
-Self-locking safety: In case of power failure/fault, the hydraulic valve is locked, and the car does not fall, so the safety is high. -Low maintenance: no complex transmission parts, only need to check the oil level/sealing, low maintenance cost.
Daily spot check
-Oil level: the oil level of the oil tank is between the upper and lower scales, and the hydraulic oil of the same type is insufficient.
-Leakage: check the pump, valve, pipeline, connector and oil cylinder for oil leakage. -Running sound: the pump and motor shall be free of abnormal sound and violent vibration after startup.
-Oil temperature: normal 30 – 55 ℃, over 60 ℃, shutdown for inspection.
-Pressure: No load/full load pressure in accordance with the nameplate, no significant fluctuations. II. Weekly maintenance
-Record parameters:Pressure, oil temperature, operating current, comparison trend.
-Cleaning: clean dust and oil on the surface of the power unit, and keep good heat dissipation.
-Fastening: re-tighten the bolts of motor, pump, valve block and pipeline joint. Semi-annual maintenance (every 6 months)
-Hydraulic oil: sample and test, and replace it if it is polluted/emulsified/discolored (commonly used 46 # anti-wear hydraulic oil).
-Oil tank: Empty and clean inner wall to remove oil sludge and impurities.
-Pumps and motors:Check the pump shaft seal, the alignment of the coupling, and the grease filling of the motor bearing.
-Safety valve: check the pressure to ensure reliable overload protection. Safety and taboo -Power-off operation: disconnect the main power supply before maintenance and hang a warning sign.
-Oil matching: only add hydraulic oil of the same model and brand, and mixing is strictly prohibited.
-It is forbidden to disassemble the valve under pressure: disassemble the pipeline and valve after pressure relief. Quick inspection of common faults
-High oil temperature: low oil level, clogged filter element, dirty cooler and high pressure.
-Insufficient pressure: oil leakage, filter element blockage, pump wear, overflow valve failure.